Job:
MVB® - Type P
Pool Heaters
Models 504-2004
Engineer:
Contractor:
Prepared By:
Model:
Date:
Indoor/Outdoor:
85% Thermal Efficiency
100% Factory Fire Tested
Pump included
standard
Minimum Acceptable Inlet Water Temperature: 105°F
Full Safety Diagnostics with History
Footprint: Less Than 5-1/2 ft2
Limited Twenty-Year Thermal Shock Warranty
Limited Five-Year Heat Exchanger Warranty
On/Off Firing
Soft-Start Modulating Controller with LCD Display
Status Display Lights
Heat Exchanger
ꢀ Bronze Headers
Control (cont.)
Temperature Controllers
B-26 TempTracker Digital Controller,
Up to 2 Heaters
ꢀ On/Off Digital Poolstat, 106°F Max
ꢀ Water Temperature Sensors (3) with
Immersion Well
ꢀ ASME HLW Stamped
160 PSIG Working Pressure
ꢀ National Board Approved
ꢀ Cupro Nickel Fin Tubing
ꢀ ASME Powder-Coated Tube Sheet
ꢀ Silicone High Temp O-Rings
ꢀ ASME Pressure Relief Valve,
125 PSIG
ꢀ Temperature and Pressure Gauge,
Shipped Loose
ꢀ Stainless Steel Evaporator Plate
ꢀ Bronze Pump (See table on pg. 2)
ꢀ Drain Valves (2)
B-21 TempTracker Digital Controller,
Up to 4 Heaters
Y-241 Electronic Sequencer,
Up to 4 Heaters
Y-281 Electronic Sequencer,
Up to 8 Heaters
Burner
ꢀ Ultra-Low NOx: Less than 20 PPM
Gas Train
ꢀ Fuel
Natural Gas
Propane
ꢀ Zero Governor Regulator
ꢀ Dual-Seat Combination Valve
ꢀ On/Off Firing with Soft-Start
Options
F-10 Low Water Cut-Off, Remote
Probe
P-
P-
S-1
Cold Water Run
H-style Bypass, Non-Ferrous
Low Gas Pressure Switch,
Manual Reset
Construction
ꢀ Air Vent
ꢀ Indoor/Outdoor Construction
ꢀ Enclosed Front Controls
ꢀ PolyTuf Powder Coat Finish
ꢀ Rear Connections (Water, Electrical,
Gas, Vent, Combustion Air)
ꢀ Design Certification
Control
S-2
High Gas Pressure Switch,
Manual Reset
ꢀ 120V, 60Hz, 1Ø, Power Supply
ꢀ 120/24V 60Hz Transformer
ꢀ Ignition Module
Regulatory Agency Requirements
3-Try – Standard
Single-Try – Option C-6
ꢀ Hot Surface Ignition (HSI)
ꢀ Remote Flame Sensor
ꢀ High Limit, Auto Reset, Adj., 140°F
ꢀ High Limit, Manual Reset, Fixed
Models 504-1504: 175°F
Models 2004: 200ºF
ꢀ On/Off Power Switch
ꢀ Flow Switch, Mtd
ꢀ Blocked Vent Pressure Switch
ꢀ Combustion Air Proving Switch
ꢀ Pump Switch
Models 504-1504: ANSI Z21.56/
CSA 4.7
Model 2004: ANSI Z21.10.3/CSA 4.3
Venting
ꢀ Vent Termination Cap
Outdoor – Option D-11
Indoor, Horizontal – Option D-15
Indoor, Vertical (by others)
ꢀ Combustion Air
In-Line Filter Kit – Option D-17
Air Intake Elbow – Option D-16
ꢀ Extractor – Optional
By others
L
W
ꢀ Pump Time Delay
ꢀ Diagnostics Panel
Not required
Catalog No.: 6000.29B
Effective: 7-15-08
Replaces: 1-1-08
|
Quantum Computer Drive DLT S4 User Guide
Radio Shack Universal Remote Kameleon 4 in One User Guide
RCA Camcorder CC6394 User Guide
RCA Radio RP5640 User Guide
Remington Power Tools Chainsaw 107624 02 User Guide
Sampo DVR DR S0426 User Guide
Samsung Headphones GH68 15048A User Guide
Sangean Electronics Weather Radio RCR 7WF User Guide
Sanyo Flat Panel Television DP50740 User Guide
Sanyo Vacuum Cleaner SC A114 User Guide